Reference | Type FOG | Type Treatment | Achievement |
---|---|---|---|
Emulsified FOG from VOR | Gravitational Methods | 80% Removal in 30 min | |
Vinci [5] | Effluent from Wastewater Plant at Miami Dade Water and Sewer Dept. | Pilot Plant using Filter Beds with High Level Disinfection, Reverse Osmosis, MF and Ultra Violet Disinfection with Advanced Oxidation | 1-11 mg/l went to 1–3 mg/l (72%) |
Shon et al. [6] | Animal fat, Sunflow and Olive Oil | Bacterial – lipase Bacterium D2D3 with aid of yeast extract and peptane | 62–94% for detention times greater than 24 h. |
Xu and Zhu [7] | FOG from Refectory | Electrocoagulation manipulating electrode distances | Over 95% FOG and 75% COD for 30 min detention at 10 mm distance |
Bayramoglu et al. [8] | Poultry Slaughter House | Electrocoagulation manipulating material of electrodes | Iron electrode removed 98% FOG but Aluminium achieved less in FOG but higher in 95% COD |
Qin et al. [9] | FOG from Restaurant | Combined electro-coagulation-electro-flotation (EC-EF) with quadratic programming system | Zero Trade Effluent |